Support : 1800-425-7002

Login

₹0 0 Cart
  • Home
  • About Us
  • Products
    • Mobile X-ray
    • Fixed X-ray
    • DR Imaging Platform
    • Surgical C-arm
    • Interventional Radiology
    • Dental X-ray
    • Patient Monitoring
    • Defibrillators
    • Respiratory Care
    • Anaesthesia Delivery
    • Diagnostic Cardiology
    • Drug Delivery
    • Electrosurgery
    • Veterinary Care
  • Specialities
    • Intensive Care
    • Radiology
    • Surgery
    • Cardiology
    • Emergency & Resuscitation
    • Dental
    • Veterinary
  • Quality
    • Certifications & Accreditations
  • OEM
  • News & Insights
  • Contact Us
  • Investor Relations
  • Home
  • About Us
  • Products
    • Mobile X-ray
    • Fixed X-ray
    • DR Imaging Platform
    • Surgical C-arm
    • Interventional Radiology
    • Dental X-ray
    • Patient Monitoring
    • Defibrillators
    • Respiratory Care
    • Anaesthesia Delivery
    • Diagnostic Cardiology
    • Drug Delivery
    • Electrosurgery
    • Veterinary Care
  • Specialities
    • Intensive Care
    • Radiology
    • Surgery
    • Cardiology
    • Emergency & Resuscitation
    • Dental
    • Veterinary
  • Quality
    • Certifications & Accreditations
  • OEM
  • News & Insights
  • Contact Us
  • Investor Relations

Support : 1800-425-7002

Become a Channel Partner

Login

₹0 0 Cart
  • Home
  • About Us
  • Products
    • Mobile X-ray
    • Fixed X-ray
    • DR Imaging Platform
    • Surgical C-arm
    • Interventional Radiology
    • Dental X-ray
    • Patient Monitoring
    • Defibrillators
    • Respiratory Care
    • Anaesthesia Delivery
    • Diagnostic Cardiology
    • Drug Delivery
    • Electrosurgery
    • Veterinary Care
  • Specialities
    • Radiology
    • Intensive Care
    • Surgery
    • Cardiology
    • Emergency & Resuscitation
    • Dental
    • Veterinary
  • Quality
    • Certifications & Accreditations
  • OEM
  • News & Insights
  • Contact Us
  • Investor Relations
  • Home
  • About Us
  • Products
    • Mobile X-ray
    • Fixed X-ray
    • DR Imaging Platform
    • Surgical C-arm
    • Interventional Radiology
    • Dental X-ray
    • Patient Monitoring
    • Defibrillators
    • Respiratory Care
    • Anaesthesia Delivery
    • Diagnostic Cardiology
    • Drug Delivery
    • Electrosurgery
    • Veterinary Care
  • Specialities
    • Radiology
    • Intensive Care
    • Surgery
    • Cardiology
    • Emergency & Resuscitation
    • Dental
    • Veterinary
  • Quality
    • Certifications & Accreditations
  • OEM
  • News & Insights
  • Contact Us
  • Investor Relations

Athena 500i

no2

Did you know

Athena 500i has 3 levels of barotrauma protection

Athena 500i has auto bypass feature to change sodalime without interruption

 

Athena 500i has internal 3 litre O2 reservoir as backup

 

Auxiliary O2  can be given even without turning ON the ventilator

 

Athena 500i has independent visual O2 indicator

Did you know

Athena 500i has 3 levels of barotrauma protection

Athena 500i has auto bypass feature to change sodalime without interruption

 

Athena 500i has internal 3 litre O2 reservoir as backup

 

Auxiliary O2  can be given even without turning ON the ventilator

 

Athena 500i has independent visual O2 indicator

Today's Best Price (With Taxes)

With standard accessories and one year warranty

₹9,20,000

  • ATHENA - 500i (IND)
Clear
Add to WishlistAlready In Wishlist
Add to Wishlist

  • 3-Gas 5-tube low-flow workstation
  • AHD with ratio control
  • Pressure, Flow & Volume waveforms
  • P-V/F-V loops with event logs
  • 6.5″ colour touch screen with rotary encoder
  • Pediatric to Adult application with 20mL to 1500mL tidal volume
  • VCV, PCV, SIMV-VC, SIMV-PC, PSV modes
  • Display of 10+ critical ventilation parameters
  • In-built spirometry with FGF compensation
  • Internal 3 litre O2 reservoir for backup supply
  • Auto bypass circle system for uninterrupted ventilation

Why Athena 500i is best in the Industry?

Get in Touch with our Product Expert

Exclusive November Offer

Exclusive Offer

Want to know how Athena 500i is unique?

FiO2 monitoring

O2 sensor is integrated with circle system for FiO2 monitoring.

Dual select-a-tec mount

Tec 5 to Tec 7 equivalent vaporiser mounting with interlock mechanism.

Auxiliary O2 output

Auxiliary O2 can be given even when ventilator is switched OFF.

Auto-bypass mechanism

Sodalime can be changed even during surgery in case of emergency.

Bag/ vent mode

Changing of ventilation & bag mode is automatic upon operation of bag/ vent switch.

Ventilation modes

VCV, PCV, SIMV-VC, SIMV-PC, PSV modes of ventilation are pre-configured. No need to buy modes at extra cost.

See Athena 500i in action

Talk to customer

brochure

Brochure

open-book

User Manual

project-management

Installation requirements

Download
Download
Download

Brochure

Download

User Manual

Download

Installation Requirements

Download

Athena 500i is a 3-gas or 2-gas machine?

Athena 500i is a 3-gas machine. O2 & N2O can be given either through central gas supply or pipeline. Air can be given through pipeline supply

Athena 500i is a 3-gas or 2-gas machine?

Athena 500i is a 3-gas machine. O2 & N2O can be given either through central gas supply or pipeline. Air can be given through pipeline supply

How many cylinders can be connected to the machine?

Athena 500i has one O2 yoke and one N2O yoke for connecting cylinders

How many cylinders can be connected to the machine?

Athena 500i has one O2 yoke and one N2O yoke for connecting cylinders

Can I give auxiliary O2 when the unit is turned OFF?

Yes, auxiliary O2 supply is independent of ventilator and can be provided even when it is turned OFF

Can I give auxiliary O2 when the unit is turned OFF?

Yes, auxiliary O2 supply is independent of ventilator and can be provided even when it is turned OFF

What are the basic & optional ventilation modes in Athena 500i?

Athena 500i is configured with five ventilation modes as standard option. There is no need to buy modes at additional cost. The five modes of ventilation are VCV, PCV, SIMV-VC, SIMV-PC and PSV

What are the basic & optional ventilation modes in Athena 500i?

Athena 500i is configured with five ventilation modes as standard option. There is no need to buy modes at additional cost. The five modes of ventilation are VCV, PCV, SIMV-VC, SIMV-PC and PSV

How do I change between ventilation modes and spontaneous mode?

The changing between ventilation mode and spontaneous is automatic when turning the bag/ vent switch in the circle breathing system

How do I change between ventilation modes and spontaneous mode?

The changing between ventilation mode and spontaneous is automatic when turning the bag/ vent switch in the circle breathing system

Should I need to change bellows separately when using for pediatrics?

No, same bellows is compatible for both adults and pediatrics

Should I need to change bellows separately when using for pediatrics?

No, same bellows is compatible for both adults and pediatrics

Contact us for more

Fill out the form below with your requirements, and our team will get back to you with tailored solutions to meet your needs.

Facebook Youtube Linkedin

SKANRAY TECHNOLOGIES LIMITED

  • Registered Office & Technology Division:
    #15-17, Hebbal Industrial Area,
    Mysore – 570016, Karnataka, India.
  • Ph: +91 821 2415559
    Fax: + 91 821 2403344
  • Healthcare Division:
    #360, KIADB Industrial Area,
    Hebbal, Mysore - 570018, Karnataka, India.
  • Ph: +91 821 2407000

PAGES

  • About Us
  • Products
  • Specialities
  • Quality
  • OEM
  • News & Insights
  • Contact Us
  • Investors Relations

SUPPORT

  • Careers

HELP

  • Search
  • Information
  • Privacy Policy

ACCOUNT

  • Wishlist
  • Login

ACCOUNT

  • Wishlist
  • Login

Copyright © Skanray Technologies Limited., 2024. All Rights Reserved.

Become a Channel Partner